TWIST-N-LOCK

NO PRE-DRILLING NECESSARY.
DRILLS DIRECTLY INTO DRYWALL.

NUL PRÉFORGE REQUIS.
PERCE SON PROPRE TOUT DANS LA CLOISON SÉCHE.

Installation Instructions / Directives d’installation

Installation Instructions

Ultimate Load Value / Valeur finale de charge

  PULLOUT / ARRACHEMENT
(lb.)
SHEAR / CISAILLEMENT
(lb.)
  GYPSUM THICKNESS
ÉPAISSEUR PANNEAU DE GYPSE
GYPSUM THICKNESS
ÉPAISSEUR PANNEAU DE GYPSE
  3/8” 1/2” 5/8” 3/8” 1/2” 5/8”
LIGHT DUTY            
Mini Twist–N–Lock™ 25 30 40 80 90 120
E–Z Mini 30 40 50 90 110 140
MEDIUM DUTY            
E–Z Zinc 40 50 75 135 150 200
Stud Solver® 40 50 75 135 150 200
HEAVY DUTY            
Twist*–N–Lock™ 65 75 80 85 110 120
E–Z Toggle™ 70 85 150 200 230 300

A safety factor of 4:1 or 25% of Ultimate values are generally accepted as a safe working load. These gures are offered as a guide and are not guaranteed by ITW. For ceiling applications use only E-Z Toggle.

Un facteur de sÛreté de 4:1 ou de 25% de valeurs nales es génÉralement acceptécomme charge de foretionnement súre. Ces informations sont présentéaaes à titre de guide seulement et ne sont pas garanties par ITW. Pour les installations au plafond, utiliser seulement E-Z Toggle (articulé)